SKU: RE-102-Conventional Fire Alarm Control Panel
2 Zone RE-102 Conventional Fire Alarm Panel
RAVEL 2 Cone RE-102 Conventional Type Fire Alarm Control Panel.
The RE-102- is a two zone fire alarm control panel build with microprocessor. This panel can support inputs for 2 wire smoke detectors, manual call points and other normally open contact devices. The outputs are Notification Appliance Circuit i.e. Siren and hooters. Ravel Panel has options to connect-Three Form-C relays 2 for fire alarm, 1 fault and can be connected RS 485 Port to interface with remote annunciator(Optional) RE-102 Conventional Fire Panel Can Supervise supply of all wiring, AC Voltage and Battery Level.
Product Feature:
- Rugged CRCA sheet with powder coated finish.
- Operates on 220v, 50Hz AC supply.
- Standby battery back up with built in charging.
- Error free Fire / Fault status in unambiguous colored LED indication.
- Switch Mode Power Supply.
- 16 X 2 LCD Display.
- Tactile key pad for easy operation.
- Main, Standby status indication.
- Low Battery visual warning with audible tone.
- Zone wise one man walk test facility.
- Relay output for actuators.
- Lamp Test facility.
- Zone Isolation facility with loop voltage cut off.
- Programmable Keypad lock.
- Programmable Auto Silence.
- Compatible to all types of conventional detectors.
QUANTITY:
RAVEL 2 Cone RE-102 Conventional Type Fire Alarm Control Panel.
2 Zone Conventional Fire Alarm Control Panel | Specification |
---|---|
AC Power | 220 VAC, 50 Hz. +10% - 15% |
Charging: Constant Voltage | – 27.6v @ 0.5A(Max) |
Charging Capacity: | 7 Amp Hour Battery Max. |
System Quiescent Current | 60mA |
Initiating Device Circuits (Zone Circuit) | All zones are Class B wiring |
Normal Operating Voltage: | Nominal 24 VDC |
Alarm Current: | 15 – 35mA threshold |
Short Circuit Current: | 42mA Maximum |
Loop resistance: | 50 ohms Maximum |
End-Of-Line Resistor: | 4.7K, 1/4watt |
Standby Current: | 6.8mA (2.4mA for Detectors) |
Notification Appliance Circuits (Sounder Circuit) | Class – B wiring |
Operating Nominal Voltage: | 24 VDC |
Hooter (NACs) output: | 1A |
End-Of-Line Resistor: | 4.7K, 1/4watt |
Relay Contact Rating: | 2Amps @ 30 VDC, 2Amps @ 30VAC (Fire – 2 No’s, Fault – 1 No.). |
System On | Green |
A.C Power On | Green |
Standby On | Green |
Hooter Fault | Yellow |
Silenced | Yellow |
Zone Fire | Red |
Zone Fault | Yellow |
Zone Isolate / Walk test | Yellow |
Similar Products

Conventional Type Fire Alarm Panels
6 Zone Fire Alarm Control Panel-Agni ProtectionRs. 10,500
Rs. 11,500-8% OFF

Conventional Type Fire Alarm Panels
4 Agni Protection Zone Conventional Fire Alarm PanelRs. 14,025
Rs. 16,500-15% OFF

Conventional Type Fire Alarm Panels
2 Zone Agni Protection Fire Alarm Control Panel.Rs. 8,500
Rs. 9,500-10% OFF